Product Specifications
- Brand
- ProMinent GmbH
- Part Number
- DULCODOS
- Product Type
- Cooling Water Treatment Controller
- Series
- DULCODOS Cooling Water
- Measured Parameters
- Conductivity, pH, ORP, Biocide (Cl₂, ClO₂, Br₂), Corrosion Rate, Corrosion Inhibitors
- Controller
- AEGIS II
- Connectivity
- LAN, Wi-Fi, Modbus RTU, DULCONNEX Cloud
- Power Supply
- 90–240 V, 50/60 Hz
- Protection Class
- IP65
- Sample Water Flow
- 15–500 L/h (Standard), 15–40 L/h (with Selective Biocide Measurement)
Product Description
The ProMinent DULCODOS Cooling Water is a pre-assembled, panel-mounted measurement and control system designed for automated treatment of cooling water in evaporative cooling systems and wet separators. It ships ready-to-connect — sensors, controller, and dosing interfaces are pre-wired and hydraulically plumbed on a single mounting panel that installs in the bypass of the circulating water line. This plug-and-play approach eliminates the field engineering and wiring time required to integrate separate sensors, controllers, and dosing pumps.
What does the DULCODOS measure and control automatically?
The system continuously monitors the core cooling water parameters — conductivity, pH, and ORP/redox potential — plus oxidative biocides (chlorine, chlorine dioxide, or bromine) via selective amperometric sensors. Direct corrosion measurement on metal coupons and indirect inhibitor detection via fluorescence sensors provide real-time insight into system protection levels. When any parameter drifts outside its setpoint, the AEGIS II controller activates the appropriate dosing pump: corrosion inhibitors to maintain the protective film, dispersants to prevent scale, or biocides to control microbiological growth.
How does the DULCODOS support regulatory compliance?
In many jurisdictions, evaporative cooling systems are subject to mandatory water quality monitoring and reporting. In Germany, the 42nd Federal Immission Control Ordinance (42. BImSchV) requires operators of cooling towers and wet separators to document water treatment parameters and submit compliance reports. The DULCODOS automates this process — the AEGIS II controller generates reports at configurable intervals and distributes them via email. With LAN, Wi-Fi, Modbus RTU (with gateways to other fieldbuses), and DULCONNEX Cloud connectivity, compliance data is accessible to facility managers, water treatment service providers, and regulatory auditors without requiring on-site visits.
What are the installation requirements?
The DULCODOS panel mounts in the bypass of the cooling water circulation line, with sample water flowing through the integrated sensor manifold at 15–500 L/h (or 15–40 L/h when selective biocide measurement is fitted). Maximum operating pressure at the sample point is 1–6 bar depending on the specific configuration, and the medium temperature must not exceed 45 °C. The system requires a 90–240 V single-phase supply and operates in ambient temperatures from +5 to +50 °C. The IP65 enclosure allows installation in the mechanical room alongside the cooling system, without requiring a separate climate-controlled cabinet.
Resources & Documentation
ProMinent DULCODOS Panel-Mounted Cooling Water Treatment Controller
Product Specifications
- Brand
- ProMinent GmbH
- Part Number
- DULCODOS
- Product Type
- Cooling Water Treatment Controller
- Series
- DULCODOS Cooling Water
- Measured Parameters
- Conductivity, pH, ORP, Biocide (Cl₂, ClO₂, Br₂), Corrosion Rate, Corrosion Inhibitors
- Controller
- AEGIS II
- Connectivity
- LAN, Wi-Fi, Modbus RTU, DULCONNEX Cloud
- Power Supply
- 90–240 V, 50/60 Hz
- Protection Class
- IP65
- Sample Water Flow
- 15–500 L/h (Standard), 15–40 L/h (with Selective Biocide Measurement)