12 month warranty Request a Quote Technical Support
US

Product Specifications

Contact Us

Product Description

The Armstrong International VERIS Verabar flow sensor, developed from aerospace technology, provides unsurpassed accuracy and reliability. With its solid one-piece construction and bullet shape, the Verabar makes flow measurement clog-free and precise.

When fluid impacts the sensor, it creates a high-pressure zone in front of the sensor. As the fluid accelerates around the sensor, a low-pressure zone is created to the sides and rear. Multiple sensing ports are positioned in these high- and low-pressure zones, and an averaged differential pressure is measured, providing a representative measurement of the true flow profile.

Clogging can occur in low-pressure ports located in or near the partial vacuum at the rear of conventional sensors. The Verabar design uniquely locates the low-pressure ports on the sides of the sensor, forward of the fluid separation point and turbulent wake area. This virtually eliminates clogging and produces an extremely stable signal, reducing noise and improving control loop performance.

Verified accuracy eliminates the need for calibration tests to characterize coefficients, with empirical test data from independent laboratories published in the VERIS Verabar Flow Test Report (VED-100). Ready to install, the Verabar can be ordered with a manifold, transmitter, local indicating meter, flow computer, and/or recorder. Complete installation is possible in less than an hour. Accuracy is ±1% of flow rate, up to ±0.5% if calibrated, with ±0.10% repeatability over the entire flow range.

Armstrong International

Verabar Flow Sensor - Averaging Pitot, ±1% | Armstrong VERIS

Averaging pitot flow sensor
MPN/Series: Verabar

Product Specifications

Manufacturer:Armstrong International

Product Type:Verabar Flow Sensor

Part Number:Verabar

Technology:Averaging pitot tube developed from aerospace technology

Accuracy:±1% of flow rate; up to ±0.5% if calibrated

Repeatability:±0.10% over entire flow range

Construction:Solid one-piece, bullet shape

Process Connections:Flanged or threaded

Pressure Rating:Up to ANSI Class 600

Features:Multiple sensing ports in high- and low-pressure zones, averaged differential pressure measurement, clog-resistant design (low-pressure ports on sides), extremely stable signal

Verified Accuracy:Empirical test data from independent laboratories published in VERIS Verabar Flow Test Report (VED-100)

Output:Mass or volumetric flow

Benefits:Low permanent pressure loss, verified flow coefficients eliminate need for calibration tests

DP Transmitter:Sold separately

Documents: Product Manual, Product Specs (2 Files)

Contact Us
Contact Us