Product Specifications
- Manufacturer
- Endress+Hauser
- Product Number
- Proline Promass I 100 / 8I1B
- Type
- Coriolis Flow Meter with In-Line Viscosity
- Nominal Diameter Range
- DN 8 to 80 (3/8 to 3in)
- Mass Flow Error (Liquid)
- ±0.1%
- Volume Flow Error (Liquid)
- ±0.1%
- Mass Flow Error (Gas)
- ±0.5%
- Density Error (Liquid)
- ±0.0005 g/cm³
- Measuring Range
- 0 to 180,000 kg/h (0 to 6600 lb/min)
- Medium Temperature Range
- -50 to +150°C (-58 to +302°F)
- Max Process Pressure
- PN 100, Class 600, 63K
- Wetted Materials
- Measuring tube Titanium grade 9, Connections Titanium grade 2
- Sensor Design
- Straight, easy cleanable single-tube system, TMB technology
- Transmitter Housing
- Robust, ultra-compact
- Ingress Protection
- IP69K
- Local Display
- Available
- Features
- Optional in-line viscosity measurement, Heartbeat Technology
- Documents
- Product Manual , Product Specs
Product Description
The E+H Proline Promass I 100 Coriolis flow meter provides the regular Coriolis outputs of mass flow, density and temperature, additionally offering in-line viscosity measurement as an optional output. The straight, easy-to-clean single-tube system with TMB technology ensures careful fluid treatment and minimal pressure loss. Combined with the smallest transmitter housing available today, it delivers full performance on the smallest footprint.
Liquid mass flow error ±0.1%, liquid volume flow error ±0.1%, gas mass flow error ±0.5%, density error ±0.0005 g/cm³. Measuring range up to 180,000 kg/h. Medium temperature range -50 to +150°C. Process pressure PN 100, Class 600. Wetted parts: measuring tube titanium grade 9, connections titanium grade 2.
Robust ultra-compact transmitter housing with IP69K protection. Local display available. Heartbeat Technology ensures measurement reliability. Ideal for system integrators, skid builders and equipment manufacturers.
High-Capacity Coriolis Flow Meter - Four-Tube, 0.05% PremiumCal, Offshore | E+H Proline Promass X 500
Product Specifications
- Manufacturer
- Endress+Hauser
- Product Number
- Proline Promass I 100 / 8I1B
- Type
- Coriolis Flow Meter with In-Line Viscosity
- Nominal Diameter Range
- DN 8 to 80 (3/8 to 3in)
- Mass Flow Error (Liquid)
- ±0.1%
- Volume Flow Error (Liquid)
- ±0.1%
- Mass Flow Error (Gas)
- ±0.5%
- Density Error (Liquid)
- ±0.0005 g/cm³
- Measuring Range
- 0 to 180,000 kg/h (0 to 6600 lb/min)
- Medium Temperature Range
- -50 to +150°C (-58 to +302°F)
- Max Process Pressure
- PN 100, Class 600, 63K
- Wetted Materials
- Measuring tube Titanium grade 9, Connections Titanium grade 2
- Sensor Design
- Straight, easy cleanable single-tube system, TMB technology
- Transmitter Housing
- Robust, ultra-compact
- Ingress Protection
- IP69K
- Local Display
- Available
- Features
- Optional in-line viscosity measurement, Heartbeat Technology
- Documents