Product Specifications
- Manufacturer
- MadgeTech
- Product Number
- RFPulse2000A
- Type
- Wireless Pulse Data Logger
- Reading Rate
- 1 second to 24 hours, samples at 100Hz
- Memory
- 16,128 readings
- Wireless Communication
- Two-way via RFC1000, 500 ft indoors / 2000 ft outdoors line of sight
- Battery Life
- 5 years typical at 10 minute reading rate
- Input Threshold
- Low below 720 mV, high above 1.070 V
- Operating Environment
- -20 to 60 °C, 0 to 95 %RH non-condensing
- Dimensions
- 88.9 x 76.2 x 24.1 mm, 116 g
- Features
- Programmable engineering units (rate per second/minute/hour/day), pulse count and rate calculation, configurable alarms, LCD with min/max/avg, direct USB interface
- Software
- MadgeTech 4 Software with Excel export, data annotation, digital calibration
- Applications
- Wind speed monitoring, energy monitoring, flow rate monitoring
- Documents
- Product Manual, Product Specs
Product Description
MadgeTech builds the RFPulse2000A around a pulse counter rather than around a sensor. The logger takes pulse output from flow meters, anemometers and other transducers, samples the input at 100 Hz, and stores the pulse total for each reading interval, with memory for 16,128 readings at a reading rate from 1 second to 24 hours.
The LCD shows the current value plus minimum, maximum and average, and the software converts a pulse stream into engineering units such as gallons per minute or miles per hour. Units can be defined as a rate per second, minute, hour or day, which is what makes long-duration logging readable. The same numbers appear on the display and in MadgeTech 4 Software, which adds graph and table views, statistics, data annotation, digital calibration and export to Excel.
Wireless range depends on the transceiver in the system. A logger reaches an RFC1000 over 500 ft indoors in a typical urban site, or 2000 ft outdoors with clear line of sight; RFC1000 units repeat to each other over 1000 ft indoors and 4000 ft outdoors. Hundreds of loggers can sit in one system once the repeaters are placed, and each logger also runs standalone on its USB link.
Two input numbers bound the application. A pulse needs a low below 720 mV and a high above 1.070 V, and resolution is 10 microseconds, which captures very short pulses while very small amplitudes fall below the threshold. One 9 V lithium battery runs 5 years at a 10 minute reading rate. The case is 88.9 x 76.2 x 24.1 mm at 116 g, rated -20 to 60 °C and 0 to 95 %RH, with FCC, IC, CE, KCC, CMIIT and LCIE approvals and time accuracy of one minute per month.
Resources & Documentation
MadgeTech RFPulse2000A Wireless Pulse Logger, 16,128 Readings, 100 Hz
Product Specifications
- Manufacturer
- MadgeTech
- Product Number
- RFPulse2000A
- Type
- Wireless Pulse Data Logger
- Reading Rate
- 1 second to 24 hours, samples at 100Hz
- Memory
- 16,128 readings
- Wireless Communication
- Two-way via RFC1000, 500 ft indoors / 2000 ft outdoors line of sight
- Battery Life
- 5 years typical at 10 minute reading rate
- Input Threshold
- Low below 720 mV, high above 1.070 V
- Operating Environment
- -20 to 60 °C, 0 to 95 %RH non-condensing
- Dimensions
- 88.9 x 76.2 x 24.1 mm, 116 g
- Features
- Programmable engineering units (rate per second/minute/hour/day), pulse count and rate calculation, configurable alarms, LCD with min/max/avg, direct USB interface
- Software
- MadgeTech 4 Software with Excel export, data annotation, digital calibration
- Applications
- Wind speed monitoring, energy monitoring, flow rate monitoring
- Documents
- Product Manual, Product Specs