Product Specifications
- Manufacturer
- Rosemount
- Product Number
- 975UF
- Type
- Ultra-Fast UV/IR Flame Detector
- Detection Range (1ft² pan fire, highest sensitivity)
- Gasoline: 66ft (20m), Diesel fuel: 49ft (15m), Methane: 26ft (8m)
- Spectral Response
- UV: 0.185–0.260 μm; IR: 2.5–3.0 μm
- Response Time
- 20 msec for flash fires
- Field of View
- Horizontal 100°, Vertical 95°
- Outputs
- 0-20 mA (with HART), RS-485 Modbus
- Heated Optics
- Eliminates condensation and icing for harsh weather operation
- Built-In-Test (BIT)
- Automatic
- Operating Temperature
- -67 to 185°F (-55 to 85°C)
- Enclosure Rating
- IP66/IP67 (EN 60529), NEMA 250 6P
- Safety Integrity
- Approved to SIL 2 (TÜV)
- Certifications
- ATEX, IECEx, FM, CSA; Meets MIL-STD-810C
- Documents
- Product Manual, Product Specs
Product Description
The Rosemount 975UF ultra-fast ultraviolet infrared flame detector can detect hydrocarbon-based fuel and gas fires, hydroxyl and hydrogen fires, as well as metal and inorganic fires. The UV/IR flame detector senses radiant energy in the short wave section of both the ultraviolet and infrared portions of the electromagnetic spectrum. The signals from both sensors are analyzed for frequency, intensity and duration. Simultaneous detection of radiant energy in both the UV and IR sensors triggers an alarm signal. The UV sensor incorporates a special logic circuit that helps prevent false alarms caused by solar radiation .
The 975UF has a wide coverage area and can detect a gasoline pan fire at 66 feet. Response time for flash fires is an impressive 20 msec. Spectral response is UV: 0.185–0.260 μm and IR: 2.5–3.0 μm. The field of view is 100° horizontal and 95° vertical .
The 975UF can perform in the harshest environmental conditions as either a stand-alone unit directly connected to an alarm system or an automatic fire extinguishing system, or as part of a more complex system. Performance can be easily adapted by changing the detector's configuration parameters via HART® or RS-485 communication. It features heated optics to eliminate condensation and icing, and automatic Built-In-Test to ensure continued reliable operation .
Built to be extremely durable and weather-resistant, it operates from -67°F to 185°F (-55°C to 85°C). It meets MIL-STD-810C for environmental conditions, is approved to Safety Integrity Level 2 (SIL 2 - TÜV), and is IP66 and IP67 rated. Hazardous area approvals include ATEX, IECEx, FM and CSA. The 975UF helps you comply with NFPA fire detection standards .
Ultra-Fast UV/IR Flame Detector - 20ms Response | Rosemount 975UF
Product Specifications
- Manufacturer
- Rosemount
- Product Number
- 975UF
- Type
- Ultra-Fast UV/IR Flame Detector
- Detection Range (1ft² pan fire, highest sensitivity)
- Gasoline: 66ft (20m), Diesel fuel: 49ft (15m), Methane: 26ft (8m)
- Spectral Response
- UV: 0.185–0.260 μm; IR: 2.5–3.0 μm
- Response Time
- 20 msec for flash fires
- Field of View
- Horizontal 100°, Vertical 95°
- Outputs
- 0-20 mA (with HART), RS-485 Modbus
- Heated Optics
- Eliminates condensation and icing for harsh weather operation
- Built-In-Test (BIT)
- Automatic
- Operating Temperature
- -67 to 185°F (-55 to 85°C)
- Enclosure Rating
- IP66/IP67 (EN 60529), NEMA 250 6P
- Safety Integrity
- Approved to SIL 2 (TÜV)
- Certifications
- ATEX, IECEx, FM, CSA; Meets MIL-STD-810C
- Documents
- Product Manual, Product Specs