Product Specifications
- Brand
- BARTEC GmbH
- Part Number
- ANTARES (Head Module 17-5174-1x0x, Connection Module 17-5164-9xx0)
- Product Type
- Remote I/O System Central Unit (RCU)
- Communication Protocols
- PROFIBUS-DP, PROFINET, Modbus TCP, EtherNet/IP
- Redundancy
- Hardware (PROFIBUS-DP variant only)
- Hot-Swap
- Yes, Head Module in Explosive Atmosphere
- Max I/O Modules
- 32
- Integrated Power
- 100 W, 24 VDC
- ATEX Certification
- II 2G Ex db eb [ib Gb] IIC T4 Gb, Zones 1/2/21/22
- Protection Rating
- IP54
Product Description
The ANTARES Rail Control Unit (RCU) is the central processing and communication hub of the BARTEC ANTARES remote I/O platform, designed for direct installation in ATEX and IECEx Zone 1 (gas) and Zone 21/22 (dust) hazardous areas without additional protective enclosures. Its hybrid Ex d (flameproof head module), Ex e (increased safety connection module), and Ex i (intrinsically safe I/O outputs) architecture integrates the CPU, communication interface, and a 100 W power supply into a single DIN-rail-mounted assembly measuring 114 × 192 × 298 mm.
What communication protocols are supported?
The RCU is available in four fieldbus variants: PROFIBUS-DP, PROFINET, Modbus TCP, and EtherNet/IP. Ethernet variants include an integrated 100BaseT switch supporting bus line topology without additional hardware. Hardware redundancy is exclusive to the PROFIBUS-DP variant — two RCUs are interconnected with a simple jumper on a common DIN rail, providing a no-single-point-of-failure central controller for safety-critical processes.
How does the hot-swap feature work in hazardous areas?
The head module — containing the CPU, communication interface, and power supply — can be replaced without disconnecting the system from voltage, even while the surrounding atmosphere remains classified as explosive. After releasing the mechanical interlock, a 15-second waiting period is observed before the head module is removed, allowing internal circuits to discharge. A replacement head module with an SD card copied from the original auto-loads the configuration and resumes operation without software intervention. The connection module and all downstream I/O modules remain powered and operational throughout.
What does the integrated power supply eliminate?
By embedding the power supply, communication processor, and intrinsic safety barriers inside the RCU, the ANTARES architecture removes the need for external galvanic isolators, safety repeaters, and separate Ex d enclosures that conventional remote I/O installations require. Each RCU powers up to 32 downstream I/O modules — analog input, digital I/O, temperature, and specialty signal types — connected via a 10+2 pole internal bus. System configuration, parameterization, and diagnostics are managed through the ANTARES Designer software via a passive USB interface.
Resources & Documentation
ATEX Zone 1 Remote I/O System with PROFIBUS & Hot-Swap Redundancy | BARTEC ANTARES
Product Specifications
- Brand
- BARTEC GmbH
- Part Number
- ANTARES (Head Module 17-5174-1x0x, Connection Module 17-5164-9xx0)
- Product Type
- Remote I/O System Central Unit (RCU)
- Communication Protocols
- PROFIBUS-DP, PROFINET, Modbus TCP, EtherNet/IP
- Redundancy
- Hardware (PROFIBUS-DP variant only)
- Hot-Swap
- Yes, Head Module in Explosive Atmosphere
- Max I/O Modules
- 32
- Integrated Power
- 100 W, 24 VDC
- ATEX Certification
- II 2G Ex db eb [ib Gb] IIC T4 Gb, Zones 1/2/21/22
- Protection Rating
- IP54