12 month warranty Request a Quote Technical Support
Sign In

Product Specifications

Product Description

Berthold EmulsionSENS is a radiometric multiphase level system for desalters and separators, where oil, emulsion and water form layers rather than a single sharp interface. Detectors outside the vessel read a density profile through the wall; Cs-137 sources sit in a dip tube inside along the measuring height.

In the aligned arrangement, sources and detectors are at the same height, and each detector outputs a local density value with accuracy around 0.002 g/cm3. In the staggered arrangement, sources sit between detectors; the system outputs density at each detector and the level of each layer, with level reproducibility of +/-25 mm. The LB 478 transmitter converts the density profile into layer levels and provides 4-20 mA HART outputs.

Detector count and source-rod length follow the measuring range and required resolution. Detectors use 304 or 316L housings and sit outside the vessel and are not exposed to process temperature. A straight dip tube serves vertical cylindrical vessels and a curved one serves horizontal vessels. Wall buildup has little effect on the reading.

Cs-137 sources are sealed in stainless-steel capsules and mounted in flexible rods. Flange-mounted shields let staff retract and lock the rods for maintenance. LB 480 detectors carry SIL 2 certification; SIL 3 can be reached by installing two detectors redundantly at each measuring position.

EmulsionSENS is a profile system, not a single-point level switch. It is engineered around vessel geometry, detector and source count, and the required density or level resolution. The accuracy figures apply to the aligned and staggered arrangements; SIL 3 depends on redundant detector installation.

Berthold Technologies
Compare

Berthold EmulsionSENS Radiometric Multiphase Level Measurement System

Radiometric Multiphase Level System
MPN/Series: EmulsionSENS

Product Specifications

Brand
Berthold Technologies GmbH & Co. KG
Model Number
EmulsionSENS
Type
Radiometric Multiphase Level Measurement System
Measuring Principle
Gamma transmission (Cs-137)
Density Accuracy
Approx. 0.002 g/cm3 (aligned)
Interface Reproducibility
+/-25 mm (staggered)
Detector
SENSseries LB 480 scintillation detector
Transmitter
LB 478, 4-20 mA HART
Safety
SIL 2 (SIL 3 with redundancy)
Applications
Oil-emulsion-water interfaces in desalters and separators
Berthold EmulsionSENS Radiometric Multiphase Level Measurement System
×