Product Specifications
Manufacturer: UE Systems
Product Number: Ultraprobe 401 (UP-401)
Type: Digital Grease Caddy
Frequency Response: Peak centered around 30 kHz, range 20-100 kHz
Display: 16-segment bar graph, calibrated decibel readout
Memory: 400 storage locations for lubrication data
Setup Menus: 18 customizable menus
Transducer: Magnetically mounted with docking station
Features: Built-in front-end lamp, swivel base, noise isolation headset for hardhat use
Documents: Product Manual, Product Specs
Product Description
The UE Systems Ultraprobe 401 Digital Grease Caddy combines advanced digital technology and data management software in an ultrasound-assisted lubrication management system. The system provides the ability to review and continually improve total lubrication practice, note warning signs, and trend successes for either condition-based or time-based preventive lubrication .
As lubrication levels in a bearing decrease, friction increases and ultrasound levels rise. The Ultraprobe 401 translates ultrasound into the audible range, enabling users to hear and recognize bearing sounds while simultaneously viewing decibel levels on the display panel. Bearings with increases over 8 dB and no change in sound quality indicate the need for lubrication .
A lube route is created, and baseline data is uploaded to the grease caddy. When decibel levels drop to the baseline level during lubrication, the user knows to stop adding lubricant. The lubrication data can then be stored and added to the bearing's history file .
The system provides a wide range of data including bearing housing lubrication capacity, type of grease used, baseline dB levels, dB levels before and after applying grease, number of strokes needed, grease cost analysis, and trend bearing condition. Bearing lubrication data is seamlessly integrated into the data management system for comprehensive monitoring .
Digital Grease Caddy - Ultrasound-Assisted Lubrication | UE Systems Ultraprobe 401
Product Specifications
Manufacturer: UE Systems
Product Number: Ultraprobe 401 (UP-401)
Type: Digital Grease Caddy
Frequency Response: Peak centered around 30 kHz, range 20-100 kHz
Display: 16-segment bar graph, calibrated decibel readout
Memory: 400 storage locations for lubrication data
Setup Menus: 18 customizable menus
Transducer: Magnetically mounted with docking station
Features: Built-in front-end lamp, swivel base, noise isolation headset for hardhat use
Documents: Product Manual, Product Specs