Product Specifications
- Manufacturer
- Endress+Hauser
- Product Number
- Proline Promass X 300 / 8X3B
- Type
- High-Capacity Coriolis Flow Meter
- Nominal Diameter
- DN 300 to 400 (12 to 16in)
- Mass Flow Accuracy (Liquid)
- ±0.10% standard, ±0.05% optional
- Volume Flow Accuracy (Liquid)
- ±0.10%
- Mass Flow Accuracy (Gas)
- ±0.25%
- Density Accuracy (Liquid)
- ±0.0005 g/cm³
- Measuring Range
- 0 to 4100 t/h (0 to 4520 tn. sh./h)
- Medium Temperature Range
- -50 to +180°C (-58 to +356°F)
- Process Pressure
- PN 100, Class 600
- Sensor Design
- Four-tube system with low pressure drop
- Exterior Design
- Complete 1.4435 (316L)
- Housing
- Compact dual-compartment with up to 3 I/Os
- Display
- Backlit with touch control and WLAN access
- Remote Display
- Available
- Documents
- Product Manual , Product Specs
Product Description
The E+H Proline Promass X 300 Coriolis flow meter provides premium accuracy (0.05%) for highest capacity and offers outstanding performance in on- and offshore oil and gas applications. With its compact transmitter, it offers high flexibility in operation and system integration: access from one side, remote display, and improved connectivity options.
The patented four-tube system with low pressure drop delivers maximum flow capacity while maintaining measurement precision. Nominal diameter DN 300 to 400 (12 to 16in). Mass flow error ±0.10% standard, ±0.05% optional. Volume flow error ±0.10%, gas mass flow error ±0.25%. Density error ±0.0005 g/cm³. Complete exterior design made of 1.4435 (316L).
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. Heartbeat Technology ensures process safety at all times.
High-Capacity Coriolis Flow Meter - Four-Tube, 0.05% Accuracy | E+H Proline Promass X 300
Product Specifications
- Manufacturer
- Endress+Hauser
- Product Number
- Proline Promass X 300 / 8X3B
- Type
- High-Capacity Coriolis Flow Meter
- Nominal Diameter
- DN 300 to 400 (12 to 16in)
- Mass Flow Accuracy (Liquid)
- ±0.10% standard, ±0.05% optional
- Volume Flow Accuracy (Liquid)
- ±0.10%
- Mass Flow Accuracy (Gas)
- ±0.25%
- Density Accuracy (Liquid)
- ±0.0005 g/cm³
- Measuring Range
- 0 to 4100 t/h (0 to 4520 tn. sh./h)
- Medium Temperature Range
- -50 to +180°C (-58 to +356°F)
- Process Pressure
- PN 100, Class 600
- Sensor Design
- Four-tube system with low pressure drop
- Exterior Design
- Complete 1.4435 (316L)
- Housing
- Compact dual-compartment with up to 3 I/Os
- Display
- Backlit with touch control and WLAN access
- Remote Display
- Available
- Documents
- Product Manual , Product Specs