Product Specifications
- Manufacturer
- Fluke Calibration
- Series
- 2 series (2100 & 2200)
- Product Type
- Benchtop Temperature Controllers for Calibration Baths
- 2100 Stability
- Better than ±0.001 °C
- 2100 Input & Resolution
- Thermistor or RTD; 0.002 °C (thermistor) / 0.01 °C (RTD); high-res mode > 0.0002 °C increment
- 2200 Stability & Range
- ±0.015 °C; –100 °C to 800 °C (RTD input only)
- Programming
- Front-panel buttons and RS-232 serial interface (standard for both)
- Power Output
- Standard IEC receptacle; 2200 delivers up to 10 A (100–230 V AC, 50/60 Hz)
Product Description
The Fluke Calibration 2 series consists of two benchtop temperature controllers — the 2100 and 2200 — designed to replace or retrofit an existing bath's control electronics and turn an average laboratory bath into a precision calibration tool. The 2100 delivers the highest stability (±0.001 °C) and ultra-sensitive response (0.00001 °C), while the 2200 offers a compact, economical alternative with ±0.015 °C stability and universal line-power flexibility for RTD-based baths operating from –100 °C to 800 °C.
2100: Highest Stability for Premium Calibration Baths
- Industry-Leading Stability: Better than ±0.001 °C in a mechanically sound bath, enabled by a solid-state PID control loop capable of detecting temperature changes as small as 0.00001 °C.
- Dual Sensor Support: Accepts thermistor (thermistor probes) for the best resolution at lower temperatures and industrial or standards-grade RTDs for wider-range calibration work. Set-point resolution is 0.002 °C with a thermistor and 0.01 °C with an RTD; high-resolution mode supports increments finer than 0.0002 °C.
- Constant Auxiliary Power: An auxiliary IEC outlet supplies uninterrupted line voltage to stirrers or other bath accessories, keeping fluid circulation stable while the controller cycles the main heater output.
2200: Compact RTD-Only Controller for Cost-Conscious Upgrades
- RTD Input, Wide Temperature Range: Operates any bath equipped with an RTD sensor from –100 °C to 800 °C with ±0.015 °C stability. Resolution is 0.01 °C on the digital display.
- Universal Line Power: Rated for 100–230 V AC, 50 or 60 Hz, with a maximum output of 10 A on a standard IEC receptacle — compatible with electrical systems worldwide without an external transformer.
- Smaller Footprint: Noticeably smaller and lighter than the 2100, making it ideal for field calibration baths, portable metrology systems, or workstations where bench space is at a premium.
Shared RS-232 Automation & Programming
- Standard Serial Interface: Both 2100 and 2200 include an RS-232 port, allowing external software to read process temperature, change set-points, and adjust control parameters — a necessity for automated calibration sequences and data logging.
- Front-Panel or Remote: All settings (control temperature, °C/°F units, proportional band, and calibration constants such as R₀ and ALPHA for RTD probes) are accessible from the four-button front panel or through the serial interface.
- Calibration Constants: The controller can be matched to a specific probe by entering its calibration coefficients, minimizing temperature offset and improving system accuracy over the full bath range.
Replace or Retrofit — Turn Good Baths into Calibration Tools
- Direct OEM Replacement: The 2100 and 2200 are designed to replace existing analogue or digital PID controllers in many stirred-liquid calibration baths, including those from Fluke's own bath product lines.
- Retrofit for Homemade/Third-Party Baths: If the bath's heater and sensor are electrically compatible, either controller can be wired in to dramatically improve stability, resolution, and automation capability.
- Typical Use Cases: Calibration laboratories, reference thermometer comparisons, industrial temperature sensor testing, and any metrology application requiring precise bath temperature control.
Resources & Documentation
Fluke Calibration 2100 Benchtop Temperature Controllers Users manual
PDF Document
Fluke Calibration 2200 Benchtop Temperature Controllers Users manual
PDF Document
2100 and 2200 Benchtop Temperature Controllers Data sheets
PDF Document
Temperature Calibration Bath and Fluid Selection Guide
PDF Document
Fluke Calibration
Fluke Calibration 2100/2200 Benchtop Temperature Controllers, 0.001 °C Stability, RS-232
Thermistor/RTD, 0.01 °C, RS-232
MPN/Series: 2100, 2200
Product Specifications
- Manufacturer
- Fluke Calibration
- Series
- 2 series (2100 & 2200)
- Product Type
- Benchtop Temperature Controllers for Calibration Baths
- 2100 Stability
- Better than ±0.001 °C
- 2100 Input & Resolution
- Thermistor or RTD; 0.002 °C (thermistor) / 0.01 °C (RTD); high-res mode > 0.0002 °C increment
- 2200 Stability & Range
- ±0.015 °C; –100 °C to 800 °C (RTD input only)
- Programming
- Front-panel buttons and RS-232 serial interface (standard for both)
- Power Output
- Standard IEC receptacle; 2200 delivers up to 10 A (100–230 V AC, 50/60 Hz)
Resources & Documentation
Fluke Calibration 2100 Benchtop Temperature Controllers Users manual
PDF Document
Fluke Calibration 2200 Benchtop Temperature Controllers Users manual
PDF Document
2100 and 2200 Benchtop Temperature Controllers Data sheets
PDF Document
Temperature Calibration Bath and Fluid Selection Guide
PDF Document