Product Specifications
Manufacturer:Additel
Product Type:Dry Well Calibrator
Part Number:ADT878
Models & Ranges:160: -40 to 320°F; 425: 91.4 to 797°F; 700: 91.4 to 1292°F
Accuracy:160: ±0.1°C at full range; 425: ±0.2°C at full range; 700: ±0.20°C at 33/425°C, ±0.25°C at 660°C
Process Calibrator Option:External reference input, two-channel readout for UUTs, full HART communicator, self-calibration of Reference Well
Communication:Wi-Fi and Bluetooth capable
Display:Color touch screen
Features:Dual-zone control, Quick-Push connectors (PC Option), set point control by reference, built-in automatic annealing (ADT878-700 only)
Documents: Product Specs
Product Description
Additel ADT878 Dry Well Calibrator has three models to choose from, ranging from -40 to 1292°F. The Process Calibrator option adds an external reference input, a two-channel readout for UUT's and a full complement of capabilities to help with everything from measuring temperature sensors, to calibrating thermocouples, self-calibrating the Reference Well and configuring HART transmitters.
The Process Calibrator option includes a full HART communicator for transmitter configuration and diagnostics. Each unit comes standard with a large touchscreen display and dual-zone control for enhanced temperature uniformity. Wi-Fi and Bluetooth capabilities enable wireless communication and remote monitoring.
Additional features include Quick-Push connectors for easy sensor connection (with PC Option), set point control by reference for improved accuracy, self-calibration capability, and built-in automatic annealing for the ADT878-700 model to maintain sensor stability over time. The rugged design ensures reliable performance in field and laboratory environments.
Resources & Documentation
Dry Well Calibrator - -40 to 1292°F, HART, Wi-Fi | Additel ADT878
Product Specifications
Manufacturer:Additel
Product Type:Dry Well Calibrator
Part Number:ADT878
Models & Ranges:160: -40 to 320°F; 425: 91.4 to 797°F; 700: 91.4 to 1292°F
Accuracy:160: ±0.1°C at full range; 425: ±0.2°C at full range; 700: ±0.20°C at 33/425°C, ±0.25°C at 660°C
Process Calibrator Option:External reference input, two-channel readout for UUTs, full HART communicator, self-calibration of Reference Well
Communication:Wi-Fi and Bluetooth capable
Display:Color touch screen
Features:Dual-zone control, Quick-Push connectors (PC Option), set point control by reference, built-in automatic annealing (ADT878-700 only)
Documents: Product Specs
















