Product Specifications
Manufacturer:Endress+Hauser
Product Number:Proline Promass A 500 / 8A5B
Type:Ultra-Low Flow Coriolis Flow Meter
Nominal Diameter:1/24 to 1/8in (DN 1 to 4)
Mass Flow Error (Liquid):±0.1%
Volume Flow Error (Liquid):±0.1%
Mass Flow Error (Gas):±0.35%
Density Error (Liquid):±0.0005 g/cm³
Measuring Range:0 to 450 kg/h (0 to 16.5 lb/min)
Medium Temperature Range:-50 to +205°C (-58 to +401°F)
Max Process Pressure:430.9 bar (6250 psi)
Wetted Materials:Measuring tube stainless steel 1.4435 (316/316L) or Alloy C22
Sensor Design:Unique self-drainable single-tube system
Transmitter Version:Remote with up to 4 I/Os
Display:Backlit display with touch control and WLAN access
Features:Heartbeat Technology, suitable for demanding continuous process control
Documents: Product Manual , Product Specs
Product Description
The E+H Proline Promass A 500 Coriolis flow meter is designed for continuous process control in very demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow rates and high pressure. With its innovative remote transmitter, Promass A 500 maximizes installation flexibility and operational safety in demanding environments.
Nominal diameter 1/24 to 1/8in (DN 1 to 4). Liquid mass flow error ±0.1%, gas mass flow error ±0.35%, density error ±0.0005 g/cm³. Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205°C (+401°F). Wetted materials: measuring tube stainless steel 1.4435 (316/316L) or Alloy C22.
Remote version with up to 4 I/Os. Backlit display with touch control. Heartbeat Technology ensures compliance and process safety at all times. Ideal for applications with smallest flow quantities in all industries.
Coriolis Meter with Viscosity - Remote 4 I/O, Titanium Tube | E+H Proline Promass I 500
Product Specifications
Manufacturer:Endress+Hauser
Product Number:Proline Promass A 500 / 8A5B
Type:Ultra-Low Flow Coriolis Flow Meter
Nominal Diameter:1/24 to 1/8in (DN 1 to 4)
Mass Flow Error (Liquid):±0.1%
Volume Flow Error (Liquid):±0.1%
Mass Flow Error (Gas):±0.35%
Density Error (Liquid):±0.0005 g/cm³
Measuring Range:0 to 450 kg/h (0 to 16.5 lb/min)
Medium Temperature Range:-50 to +205°C (-58 to +401°F)
Max Process Pressure:430.9 bar (6250 psi)
Wetted Materials:Measuring tube stainless steel 1.4435 (316/316L) or Alloy C22
Sensor Design:Unique self-drainable single-tube system
Transmitter Version:Remote with up to 4 I/Os
Display:Backlit display with touch control and WLAN access
Features:Heartbeat Technology, suitable for demanding continuous process control
Documents: Product Manual , Product Specs