12 month warranty Request a Quote Technical Support
Sign In

Product Specifications

Product Description

The IC225SRD130 is a PACSafe interface module purpose-built for connecting light curtains, laser scanners, and other OSSD-equipped safety devices to the PACSafe safety system. It accepts a dual-channel OSSD input pair and provides 3 normally open hard-contact relay outputs rated at 6 A — suitable for directly switching safety contactors, motor starters, or solenoid valves without intermediate relays.

Why use a dedicated interface module instead of wiring directly to the controller?

Dedicated interface modules offload the OSSD pulse-test monitoring and External Device Monitoring (EDM) logic from the main safety controller. The SRD130 handles the high-speed pulse validation locally — confirming that each OSSD channel switches within 5 ms — and provides isolated relay outputs that protect the controller from field wiring faults. For machines with multiple light curtains (e.g. perimeter guarding with separate entry/exit curtains), distributing interface modules near each optoelectronic device reduces wiring complexity and keeps the safety controller focused on logic execution rather than I/O signal conditioning.

What does External Device Monitoring provide?

The EDM input monitors the normally closed auxiliary contacts of externally connected contactors or relays, verifying that they have actually dropped out when the safety outputs are de-energized. If a contactor welds closed, EDM detects the fault at the next demand on the safety function and prevents the system from restarting — maintaining SIL3/PL e integrity through the entire safety chain, not just the controller outputs.

Related Products

  1. Emerson IC225SDL720 — Mid-Range SIL3 Safety Output, 4 PNP Channels
  2. Emerson IC225SDL740 — 8-Channel Solid State Safety Output Module
  3. Emerson IC225SRD121 — Light Curtain Interface, 2NO+1NC 6A Contacts
  4. Emerson IC225SXE262 — Expandable SIL3 Controller, 26 Safe Inputs

Resources & Documentation

Emerson
Compare

PACSafe Interface Module for Light Curtains, 3NO Contacts | Emerson IC225SRD130

Light Curtain Interface, 3NO 6A Contacts
MPN/Series: IC225SRD130

Product Specifications

Brand
Emerson Electric Co.
Part Number
IC225SRD130
Type
Safety Interface Module
Series
PACSafe
Function
Light Curtain & OSSD Interface
Safe Outputs
3NO (Relay, 6 A at 240 VAC / 24 VDC)
Safe Inputs
2 (OSSD Pair, 50 mA at 24 VDC)
Safety Rating
Category 4, PL e / SIL CL 3