12 month warranty Request a Quote Technical Support
Sign In

Product Specifications

Product Description

The Ametek Jofra RTC-156 and RTC-157 reference temperature calibrators combine Ametek's unparalleled experience with temperature calibration with cutting edge technological features creating the most sophisticated dry block temperature calibrators on the market.

The RTC-156 has a temperature range of -30° to 155°C, while the RTC-157 has a temperature range of -45° to 155°C. Both units boast outstanding accuracy (±0.04°C with external sensor) and stability (±0.005°C) while featuring Ametek's Dynamic Load Compensation (DLC) system that provides perfect temperature uniformity in the insert no matter the number or size of the sensors immersed. The calibrators also offer unique intelligent sensors for plug ‘n' play connectivity, an easy-to-read full-color 5.7-inch VGA display, and a USB connection for improved communications and software downloads.

The RTC-156 and RTC-157 are available in three configurations: RTC-A reference temperature calibrator, RTC-B reference temperature calibrator with input for reference sensor, DLC sensor and sensors-under-test, and RTC-C reference temperature calibrator with input for reference sensor and DLC sensor. Both the STS-200 and DLC sensors contain all individual calibration data regarding the sensor, allowing users to change the reference sensor and be up and running immediately.

The units feature a rugged, lightweight design and multi-hole inserts that cover most commonly used sensor sizes. Heating and cooling times are optimized for efficiency, with RTC-157 achieving -45°C to 23°C in just 7 minutes.

Ametek
Compare

Reference Temperature Calibrator - -45 to 155°C, DLC | Ametek Jofra RTC-156/157

High-accuracy low-temp dry block
MPN/Series: RTC-156 / RTC-157

Product Specifications

Manufacturer
Ametek
Product Type
Reference Temperature Calibrator
Part Number
Jofra RTC-156 / RTC-157
Temperature Ranges
RTC-156: -30 to 155°C (-22 to 311°F); RTC-157: -45 to 155°C (-49 to 311°F)
Accuracy (with external ref sensor)
±0.04°C
Accuracy (with internal ref sensor)
±0.10°C
Stability
±0.005°C
Radial Homogeneity
0.01°C
Resolution
1°, 0.1°, 0.01°, or 0.001°
Heating Time (RTC-156)
-33 to 23°C: 4 min, 23 to 155°C: 15 min
Heating Time (RTC-157)
-45 to 23°C: 7 min, 23 to 155°C: 8 min
Immersion Depth
160 mm
Technology
Active dual-zone block, Dynamic Load Compensation (DLC), 4-wire True-Ohm-Measurement
Models
RTC-A (basic), RTC-B (with inputs for ref sensor, DLC, UUTs), RTC-C (with inputs for ref sensor and DLC)
Communication
USB 2.0 device, USB 2.0 host, Ethernet LAN, SD slot
Documents
Product Specs
Reference Temperature Calibrator - -45 to 155°C, DLC | Ametek Jofra RTC-156/157