The Siemens 7KT1666 is the MID-certified Modbus RTU variant of the PAC1600 series with direct 80 A connection. It puts billing-grade energy data — active/reactive/apparent energy, plus instantaneous voltage, current, and power factor — directly onto the RS-485 bus for PLC and SCADA integration.

Modbus RTU for energy data — what registers do I get?

Modbus RTU (and ASCII) over RS-485 gives you register-level access to all measured values: total and partial energy counters (active, reactive, apparent), instantaneous per-phase and three-phase values (voltage, current, power, power factor, frequency), and status/diagnostic registers. The Modbus map follows standard conventions for energy meters, making integration with Siemens and third-party PLCs straightforward. Baud rates up to 38400 bps are supported.

Why choose this over the M-Bus MID variant?

The choice between Modbus RTU and M-Bus comes down to the system architecture: Modbus RTU is the industrial automation standard — every PLC, RTU, and HMI speaks it natively. M-Bus is the building automation standard — it excels at long multi-drop bus runs with many meters. Pick the 7KT1666 (Modbus) when the meter reports to a PLC, SCADA system, or industrial gateway. Pick the 7KT1668 (M-Bus) when it joins a building-wide meter network with an M-Bus master. Both are MID certified for billing.

Parameter 7KT1666 (Modbus, MID) 7KT1665 (Modbus, no MID) 7KT1662 (Modbus, 5A, MID)
Current Input 80 A direct 80 A direct 5 A (CT)
Communication Modbus RTU/ASCII Modbus RTU/ASCII Modbus RTU/ASCII
MID Certified Yes (Class B) No Yes (Class 0.5s + B)
Accuracy Class 1 / Class B Class 1 Class 0.5s / Class B
Typical System PLC/SCADA with billing PLC/SCADA monitoring PLC/SCADA with billing + CTs

Frequently Asked Questions

How do I configure the Modbus parameters on the 7KT1666?

Modbus address (1–247), baud rate (2400–38400), parity (none/even/odd), and stop bits are configurable via the front-panel buttons and LCD menu, or through Modbus itself once the initial address is known. The factory default is typically address 1, 9600 baud, even parity, 1 stop bit.

Can I mix 7KT1666 meters with other Modbus devices on the same RS-485 bus?

Yes. The meter is a standard Modbus RTU slave — it coexists with any other Modbus slave devices on the same RS-485 segment, provided each has a unique address. The RS-485 wiring follows standard daisy-chain topology with termination resistors at both ends of the bus.

Siemens
Compare

Siemens 7KT1666 PAC1600 3-Phase Energy Meter — Modbus RTU, 80A Direct, MID Certified

Modbus RTU with MID billing certification for direct 80 A three-phase measurement
MPN/Series: 7KT1666

Product Specifications

Brand
Siemens
Part Number
7KT1666
Product Type
3-Phase Energy Meter
Series
SENTRON PAC1600
Current Input
80 A (direct-connected)
Communication Interface
Modbus RTU/ASCII (RS-485)
MID Certification
Yes (EN 50470-3 Class B)
Accuracy (Active Energy)
Class B (MID), Class 1 (IEC/EN 62053-21)
Nominal Voltage
230 V L-N / 400 V L-L
Frequency
50 Hz (MID)
Dimensions (L × W × H)
90 × 72 × 63 mm
Weight
360 g
Mounting
DIN Rail
Siemens 7KT1666 PAC1600 3-Phase Energy Meter — Modbus RTU, 80A Direct, MID Certified