Product Specifications
- Brand
- Eastern Instruments
- Part Number
- QVT
- Type
- Multivariable Differential Pressure Transmitter for Air and Gas Flow
- DP Operating Range
- 10000:1, 0.0009 to 9.0 in WC
- 4-20 mA Span
- 0-0.05 to 0-8.0 in WC (160:1)
- Flow Accuracy
- +/-0.50 percent of reading over 100:1 DP (10:1 flow) range
- DP Sensor Accuracy
- +/-0.05 percent reading and +/-0.005 percent URL at 25 degrees C (high/extreme accuracy model)
- Output
- 4-20 mA compensated flow or DP, 10 updates per second
- Power Supply
- loop-powered 8.8 to 42.5 VDC
- Temperature Input
- external Class A, 3-wire Pt100 RTD (up to 4 variables total)
- Process Connection
- 1/4 NPT high and low ports; pipe, panel or flow-element mounting
- Pressure Limits
- common mode +/-10 PSI, max DP 4 PSI, 5 to 25 psia operation
Product Description
The Eastern QVT is a multivariable differential pressure transmitter for air and gas flow at or near atmospheric pressure, with operation specified at 5 to 25 psia. Its process seal isolates the sensors without a diaphragm seal, which the maker cites as a way to avoid the condensate that can distort sensor readings in low-DP service. The DP operating range spans 10000:1, from 0.0009 to 9.0 in WC.
Flow accuracy is plus or minus 0.50 percent of reading over a 100:1 DP range, equivalent to 10:1 in flow, and the DP sensor resolves down to 0.0001 in WC at one count. The high and extreme accuracy sensor versions are rated plus or minus 0.05 percent of reading and plus or minus 0.005 percent of URL at 25 degrees C. The 10000:1 figure describes the DP measuring range, not the accuracy band.
The transmitter measures up to 4 process variables and computes fully compensated mass flow from differential pressure, absolute pressure and temperature. Absolute pressure comes from an integral sensor on the low port of the flow element, while temperature comes from an external Class A, 3-wire Pt100 RTD that must be wired in. Density is computed from measured pressure and temperature; the flow calculation follows process changes rather than fixed constants.
Any DP-based primary element can be used, including the Eastern VAP averaging pitot and HBP flow conditioner or a third-party DP flow element. The transmitter outputs either raw DP or fully compensated mass flow on a loop-powered 4-20 mA circuit running from 8.8 to 42.5 VDC; flow and DP update 10 times per second, while absolute pressure and temperature update 5 times per second.
Ae and the 4-20 mA full-scale value are set from the push buttons on the LCD, which rotates 270 degrees independently of a head that rotates 180 degrees. Mounting is by pipe, panel or direct attachment to the flow element, typically with 3- or 5-way valves; the high and low process ports are 1/4 NPT. Maximum common-mode pressure is plus or minus 10 PSI and maximum differential pressure is 4 PSI. The brand is Eastern Instruments.
Eastern QVT Multivariable Pressure Transmitter, 10000:1 DP Range
Product Specifications
- Brand
- Eastern Instruments
- Part Number
- QVT
- Type
- Multivariable Differential Pressure Transmitter for Air and Gas Flow
- DP Operating Range
- 10000:1, 0.0009 to 9.0 in WC
- 4-20 mA Span
- 0-0.05 to 0-8.0 in WC (160:1)
- Flow Accuracy
- +/-0.50 percent of reading over 100:1 DP (10:1 flow) range
- DP Sensor Accuracy
- +/-0.05 percent reading and +/-0.005 percent URL at 25 degrees C (high/extreme accuracy model)
- Output
- 4-20 mA compensated flow or DP, 10 updates per second
- Power Supply
- loop-powered 8.8 to 42.5 VDC
- Temperature Input
- external Class A, 3-wire Pt100 RTD (up to 4 variables total)
- Process Connection
- 1/4 NPT high and low ports; pipe, panel or flow-element mounting
- Pressure Limits
- common mode +/-10 PSI, max DP 4 PSI, 5 to 25 psia operation