The KROHNE ENVIROMAG 2000 Electromagnetic Flow Meter is suitable for either clean, homogeneous or dirty, non-homogeneous flow applications. Configurable into a number of system designs, it is designed for use with either the KROHNE IFC 100 or KROHNE IFC 300 flow converters .

The ENVIROMAG 2000 features either polyurethane or hard rubber liners and sturdy ASME steel flanges in either 150 lb or 300 lb pressure ratings. Standard features include low investment and operating costs, easy and quick installation, and absolutely maintenance-free operation with no mechanically moving parts .

Applications include water and wastewater treatment, with suitability for process temperatures up to 176°F and pressures up to 580 psig. The meter carries an IP67 protection rating equivalent to NEMA 6, suitable for short-time submersion, with IP68 available for flood-prone installations .

The ENVIROMAG 2000 is IDWR-certified for water users in regulated areas of Idaho, having passed testing at Utah State's NIST traceable lab. It is manufactured according to ISO 9000 certified quality assurance standards and features rugged liners suitable for almost any water and wastewater application, unaffected by solids, fibers, slurries, and debris .

KROHNE

Electromagnetic Flow Meter - Water/Wastewater, 1-24 in | KROHNE ENVIROMAG 2000

Magmeter for Water/Wastewater, 1-24 in, IP67
MPN/Series: ENVIROMAG 2000

Product Specifications

Manufacturer: KROHNE

Model: ENVIROMAG 2000

Type: Electromagnetic Flow Meter

eter Size: DN25 to DN600 (1 to 24 inches), larger sizes on request

Flange Connections: ASME 150 lb or 300 lb

Liner Materials: Hard rubber or polyurethane

Electrode Material: 316L stainless steel (standard), Hastelloy C22 (optional)

Minimum Conductivity: ≥1 μS/cm (general), ≥20 μS/cm (water)

Flow Velocity Range: 0.3 to 12 m/s

Accuracy: ±0.2% of MV (with IFC 300), ±0.3% of MV ±1 mm/s (with IFC 100)

Process Temperature: Up to 176°F (80°C)

Process Pressure: Up to 580 psig (40 bar)

Enclosure Rating: IP67 (NEMA 6), IP68 (NEMA 6P) optional

Output: 4-20 mA + HART, pulse/frequency, status (converter dependent)

Power Supply: 100-230 VAC 50/60Hz, or 24 VDC

Compatible Converters: IFC 100, IFC 300

Certifications: NSF drinking water, IDWR, ISO 9000, NIST traceable calibration (EN 17025)