Product Specifications
- Brand
- Siemens
- Part Number
- 6SL3520-0XE02-2AA0
- Type
- Frequency Converter / Distributed Drive
- Series
- SINAMICS G115D
- Power Rating
- 2.2 kW (5.9 A rated / 11.8 A overload)
- Voltage
- 3-phase 380–480 V
- Frame Size
- FSB Fanless (425×180×134 mm)
- Cooling
- Natural Convection
- Communication
- I/O Control (Digital/Analog Signals)
- Protection
- IP65
- Weight
- 7.12 kg
Product Description
With XE02-2AA0, the XE02 debut is complete — SINAMICS G115D XE02 at 2.2kW FSB fanless arrives with all three G115D communication interfaces confirmed on first sight. XE02-2AA0 is the I/O Control variant — no fieldbus, no network configuration, no PROFINET engineering tool. Digital inputs handle start/stop and direction; an analog input (0–10V or 4–20mA) sets the speed reference. For a conveyor section that only needs to run forward at variable speed, this is the shortest path from panel to production.
Why would an engineer choose I/O Control on a 2.2kW drive in 2026?
Because not every drive needs to be on a network. A standalone feed conveyor driven by a photocell, a pump controlled by a float switch, an exhaust fan triggered by a thermostat — these are single-drive applications where fieldbus integration adds engineering hours without adding operational value. XE02-2AA0 delivers the same 2.2kW of fanless FSB distributed drive power as its PROFINET and AS-Interface siblings, but the control interface is three wires — start, direction, and speed. Any maintenance technician can troubleshoot it with a multimeter. For machine builders exporting to regions where fieldbus-trained personnel are scarce, I/O Control reduces commissioning and after-sales friction.
How does XE02-2AA0 complete the XE02 picture?
XE02 debuts in this batch with all three communication variants simultaneously — AA0 (I/O Control), AF0 (AS-Interface), and AB0 (PROFINET). This is unusual; most G115D sub-series reveal their variants over multiple batches. XE02 arriving fully formed means the XE0x sub-series at 2.2kW has no gaps — engineers can specify the exact comm interface they need from day one. XE02 parallels XE42 (XE4x), 1XA02 (1XA0x), 1XA22 (1XA2x), XH22 (0XH current), and XN02 (0XH intermediate) — six parallel catalog codes for the same 2.2kW fanless FSB hardware.
Frequently Asked Questions
Can I add fieldbus capability to XE02-2AA0 later?
No — the communication interface is built into the drive at the hardware level and is not field-upgradable. If there is any chance the application will later need PROFINET or AS-Interface, specify the AB0 or AF0 variant upfront. The AA0 variant is the right choice only when the control architecture is definitively I/O-based.
What is the difference between XE02 and XE42?
The digit after "XE" — "0" vs "4" in the PN position 7. Both are XE-catalog G115D drives on the same hardware platform. XE0x (XE01–XE07) and XE4x (XE40–XE47) are parallel sub-series within the XE family. Same frames, same power ratings, same communication variants. The distinction is Siemens catalog organization, not hardware.
Related Products
Resources & Documentation
SINAMICS G115D 2.2kW Fanless FSB Distributed Drive with I/O Control 6SL3520-0XE02-2AA0
Product Specifications
- Brand
- Siemens
- Part Number
- 6SL3520-0XE02-2AA0
- Type
- Frequency Converter / Distributed Drive
- Series
- SINAMICS G115D
- Power Rating
- 2.2 kW (5.9 A rated / 11.8 A overload)
- Voltage
- 3-phase 380–480 V
- Frame Size
- FSB Fanless (425×180×134 mm)
- Cooling
- Natural Convection
- Communication
- I/O Control (Digital/Analog Signals)
- Protection
- IP65
- Weight
- 7.12 kg