Product Specifications
- Manufacturer
- Endress+Hauser
- Product Number
- Proline Promag H 100 (5H1B)
- Type
- Hygienic Electromagnetic Flow Meter
- Nominal Diameter
- DN 2 to 150 (1/12 to 6 in)
- Measuring Range
- 0.015 to 2650 gal/min (0.06 dm³/min to 600 m³/h)
- Maximum Measured Error
- Standard: ±0.5% o.r. ± 1 mm/s; Optional: ±0.2% o.r. ± 2 mm/s
- Medium Temperature Range
- -4 to 302°F (-20 to 150°C)
- Liner Material
- PFA
- Wetted Materials
- Electrodes: 316L, Alloy C22, Tantalum, Platinum
- Outputs
- 4-20 mA HART (active), Pulse/frequency/switch output (passive)
- Digital Communication
- HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
- Enclosure Rating
- IP66/67, Type 4X standard; IP69 optional
- Documents
- Product Manual, Product Specs
Product Description
The E+H Proline Promag H 100 Electromagnetic Flow Meter is designed for hygienic applications with highest requirements in the food and beverage and life sciences industries. The ultra-compact transmitter provides full performance on the smallest footprint and enables seamless system integration, making it the preferred choice for skid builders, equipment manufacturers and system integrators .
The meter features multivariable measurement for flow, temperature, and conductivity. The bidirectional measuring principle is independent of pressure, density, temperature, and viscosity. With no moving parts, it is maintenance-free and suffers no pressure loss due to cross-section constriction .
The PFA liner handles media temperatures from -4 to 302°F. Standard accuracy is ±0.5% o.r. ± 1 mm/s, with optional ±0.2% o.r. ± 2 mm/s. The transmitter offers full access to process and diagnostic information via freely combinable I/Os and fieldbuses including HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, and PROFINET .
Heartbeat Technology ensures compliance and process safety at all times. The meter is housed in an IP66/67, Type 4X enclosure standard, with IP69 available as an option. Hazardous area approvals include ATEX, IECEx, cCSAus, INMETRO, and EAC. Predecessors include Promag 50H and Promag 53H .
Related Products
Hygienic Electromagnetic Flow Meter - Food/Beverage, 1/12-6in | E+H Proline Promag H 100
Product Specifications
- Manufacturer
- Endress+Hauser
- Product Number
- Proline Promag H 100 (5H1B)
- Type
- Hygienic Electromagnetic Flow Meter
- Nominal Diameter
- DN 2 to 150 (1/12 to 6 in)
- Measuring Range
- 0.015 to 2650 gal/min (0.06 dm³/min to 600 m³/h)
- Maximum Measured Error
- Standard: ±0.5% o.r. ± 1 mm/s; Optional: ±0.2% o.r. ± 2 mm/s
- Medium Temperature Range
- -4 to 302°F (-20 to 150°C)
- Liner Material
- PFA
- Wetted Materials
- Electrodes: 316L, Alloy C22, Tantalum, Platinum
- Outputs
- 4-20 mA HART (active), Pulse/frequency/switch output (passive)
- Digital Communication
- HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
- Enclosure Rating
- IP66/67, Type 4X standard; IP69 optional
- Documents
- Product Manual, Product Specs