12 month warranty Request a Quote Technical Support
US
Siemens

3VA2

Siemens 3VA2 MCCBs provide electronic overcurrent protection in a 160 A frame, with 63 A variants spanning six ETU trip unit models from basic LI to full LSIG selectivity. 3-pole and 4-pole configurations offer 55 kA or 85 kA breaking capacity at 415 V, with terminal, clamp, and nut-keeper connections. Integrated N-protection and ground-fault detection on select models extend coverage to main and feeder applications. The ETU electronic platform delivers temperature-compensated tripping independent of ambient conditions for simplified network coordination.

Products in This Series

Click product for full specifications. Select items to request a bulk quote.

0 Products
Select Image Product Key Specifications Action
3VA2063-5JP32-0AA0 3VA2063-5JP32-0AA0 Siemens 3VA2 3-Pole 63A 55kA MCCB, ETU550 LSI with Optional N PDF Siemens 3VA2 3-pole 63A 55kA MCCB with ETU550 LSI trip unit: overload Ir 25-63A, short-circuit Isd 0.6-10×In, instantaneous Ii 1.5-12×In. Neutral protection optionally with external CT, up to 160%. Nut keeper kit terminals. For industrial line protection with optional communication. View Product
3VA2063-6HL42-0AA0 3VA2063-6HL42-0AA0 85kA 4-Pole 63A MCCB with Nut-Keeper Terminals, ETU320 LI – PDF This 4-pole 63A H-class MCCB combines 85kA breaking with basic ETU320 LI protection and nut-keeper terminals for direct busbar mounting. Neutral conductor is adjustable (OFF/100%). No communication, no ground-fault — a robust, cost-effective main breaker for high-fault industrial panels. View Product
3VA2063-5JP42-0AA0 3VA2063-5JP42-0AA0 Siemens 3VA2 4P 63A 55kA MCCB, ETU550 LSI with Adjustable N-P PDF Siemens 3VA2 4-pole 63A 55kA MCCB with ETU550 LSI trip unit: overload Ir 25-63A, short-circuit Isd 0.6-10×In, instantaneous Ii 1.5-12×In. Adjustable neutral protection (OFF, 40%-160%). Nut keeper kit terminals. For industrial distribution with neutral monitoring and optional communication. View Product
3VA2063-5HL46-0AA0 3VA2063-5HL46-0AA0 Siemens 3VA2 4P 63A 55kA MCCB ETU320 LI with N-Protection Ter PDF Siemens 3VA2 4-pole 63A 55kA MCCB with ETU320 LI trip unit. Overload Ir 25-63A, instantaneous Ii 1.5-12 x In. Neutral protection adjustable (OFF, 100%). Terminal connection. For standard line protection without communication or G-fault. View Product
3VA2063-5HM46-0AA0 3VA2063-5HM46-0AA0 Siemens 3VA2 4P 63A 55kA MCCB ETU330 LIG Ground-Fault Protect PDF Siemens 3VA2 4-pole 63A 55kA molded case circuit breaker with ETU330 LIG trip unit. Overload Ir 25-63A, short-circuit Ii 1.5-12 x In, ground-fault Ig 0.25-1 x In (tg 0.1/0.3s). Adjustable neutral OFF/100%. Terminal connection. For low-voltage distribution with earth-fault detection. View Product
3VA2063-5KQ36-0AA0 3VA2063-5KQ36-0AA0 ETU860 LSIG 3-Pole 63A MCCB, M-Class 55kA, Terminal – Sieme PDF Siemens 3VA2 ETU860 3-pole 63A M-class MCCB with full LSIG protection: Ir 25-63A, Isd 0.6-10xIn, Ii 1.5-12xIn, switchable ground-fault Ig 0.25-1xIn (tg 0.05-0.8s). ETU860 trip unit with communication and measurement functions. Terminal connection, for system protection in industrial distribution. View Product
3VA2063-5KQ42-0AA0 3VA2063-5KQ42-0AA0 ETU860 LSIG 4-Pole 63A MCCB, M-Class 55kA, Nut-Keeper – Sie PDF Siemens 3VA2 ETU860 LSIG 4-pole 63A M-class MCCB with nut keeper kit: Ir 25-63A, Isd 0.6-10xIn, Ii 1.5-12xIn, switchable ground-fault Ig 0.25-1xIn (tg 0.05-0.8s). N-conductor adjustable OFF-160%. Communication-capable. For 4-pole system protection in industrial distribution. View Product
3VA2063‑5KQ46‑0AA0 3VA2063‑5KQ46‑0AA0 ETU860 LSIG 4‑Pole 63A MCCB, M‑Class 55kA, Terminal – S PDF Siemens 3VA2 ETU860 LSIG 4‑pole 63A M‑class MCCB. Full LSIG protection: Ir 25‑63A, Isd 0.6‑10×In, Ii 1.5‑12×In, Ig 0.25‑1×In (tg 0.05‑0.8s, switchable). N‑conductor adjustable OFF‑160%. Terminal connection, communication‑capable. For system protection where monitoring counts. View Product
3VA2063-5JP36-0AA0 3VA2063-5JP36-0AA0 Siemens 3VA2063-5JP36-0AA0 3-Pole 63A MCCB with ETU550 LSI Pr PDF Siemens 3VA2063-5JP36-0AA0 is a 3-pole 63A circuit breaker with the intelligent ETU550 (LSI) trip unit. It provides 55kA breaking capacity and an integrated display for power monitoring in industrial applications. View Product
3VA2063-6HL36-0AA0 3VA2063-6HL36-0AA0 85kA 3-Pole 63A MCCB, ETU320 LI, Clamp Connection – Siemens PDF A compact 3-pole 63A H-class MCCB with simple ETU320 LI protection: adjustable overload and instantaneous short-circuit, clamp terminals, no neutral, no communication. Designed for high-fault industrial panels where space and straightforward protection are the priority. View Product
3VA2063-5KP32-0AA0 3VA2063-5KP32-0AA0 Siemens 3VA2063-5KP32-0AA0 3-Pole 63A MCCB with ETU850 LSI Pr PDF Siemens 3VA2063-5KP32-0AA0 is a 3-pole, 63A molded case circuit breaker with the premium ETU850 (LSI) trip unit. It features integrated energy measurement, 55kA breaking capacity, and modular connectivity for advanced industrial power systems. View Product
3VA2063-5JQ42-0AA0 3VA2063-5JQ42-0AA0 Siemens 3VA2 4-Pole 63A MCCB, ETU560 LSIG, 55kA, N-Protection PDF Siemens 3VA2 4-pole 63A, 55kA MCCB with ETU560 LSIG trip unit: adjustable N-conductor (OFF/≤160%), switchable ground-fault (Ig 0.25-1xIn, tg 0.05-0.8s). Nut keeper kit termination. For industrial distribution requiring neutral & ground-fault monitoring. View Product